From: Michael Stout (michaelgstout@hotmail.com)
Date: Sun Jun 04 2006 - 04:36:17 ART
The most wise advice ive read on this subject indicates that you should
multiply each value by the same factor, 1.5 in this case. So
30 * 1.5
180 * 1.5
180*1.5
240* 1.5
However, despite this reasoning, i agree that your solution is valid.
--------------------------------------------------------------------
From: Sami <sy1977@gmail.com>
Reply-To: Sami <sy1977@gmail.com>
To: "Cisco certification" <ccielab@groupstudy.com>
Subject: RIP timers
Date: Sat, 3 Jun 2006 15:41:35 +0200
Hello
Just wondering if lab says rip update should be send every 45
second.. is it
ok to config timer like this ?
rip > timer basic 45 180 180 240
Doc CD says invalid and holdown timer should be 3 times of update
time and
flush should be more than invaild timer.