RE: CSS11506 console w/ 2610XM NM-32A

From: Zahid Hassan (zhassan@gmx.net)
Date: Thu May 04 2006 - 19:07:10 ART


Ben,

This works for me fine with the following line config:

line 33 64
 session-timeout 10
 no exec
 login authentication async
 transport input all
line 97 112
 session-timeout 10
 no exec
 login authentication async
 transport input all

Regards,

Zahid

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Ben
Sent: Tuesday, May 09, 2006 10:39 PM
To: ccielab@groupstudy.com
Subject: OT: CSS11506 console w/ 2610XM NM-32A

Hi Group,

Has anyone successfully setup their 2511 or 26xx with NM-32A to provide
console access to their CSS11506/3/1?

I can:
1.) Get access to the CSS11506 through a PC using a standard rollover
console cable
2.) Use the existing port/patch cable (coupled together at a patch
panel) on the NM-32A to connect to other devices using the 9600/8/N/1
settings

When I connect the NM-32A, I can see data coming from the CSS when it
boots - but I am not able to send responses back. No 'yes' or 'no'
answers, no enter key.. nothing.

line config:

line 33 64
 exec-timeout 0 0
 no exec
 transport input all
 telnet break-on-ip
 telnet sync-on-break
 telnet ip-on-break
 flowcontrol hardware

Ideas, thoughts? Might this be a cabling issue?

TIA

Ben