From: Brian Dennis (bdennis@internetworkexpert.com)
Date: Mon Jan 23 2006 - 17:15:54 GMT-3
You do not need to do a "write mem" for the configuration register to be
saved since the configuration register isn't stored in the startup
configuration file.
HTH,
Brian Dennis, CCIE #2210 (R&S/ISP-Dial/Security)
bdennis@internetworkexpert.com
Internetwork Expert, Inc.
http://www.InternetworkExpert.com
Toll Free: 877-224-8987
Direct: 775-745-6404 (Outside the US and Canada)
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Nambi Appachigounder
Sent: Monday, January 23, 2006 3:08 AM
To: Kayode Oladipo; ccielab@groupstudy.com
Subject: Re: problem with 3640 baud rate
Issue "write mem" and i think it should work.
Regards,
Nambi
--- Kayode Oladipo <kayoladipo@hotmail.com> wrote:
> I have a problem with a 3640 router that after
> booting it changes the
> console line from the default 9600 to 115200. I've
> changed console baud
> rate to the default of 9600 from ROMMON and I even
> changed the
> config-register to 0x2102 after bootup but each time
> I reload it, I still
> get the baud rate of 115200. This is what I see when
> I do a sh ver.
>
> Configuration register is 0x2102 (will be 0x3962 at
> next reload).
>
> Any assistance will be appreciated.
>
> Cheers,
>
> Kayode
>
>
This archive was generated by hypermail 2.1.4 : Wed Feb 01 2006 - 07:45:50 GMT-3