From: simon hart (simon@harttel.com)
Date: Fri Sep 02 2005 - 13:55:53 GMT-3
Dave what is the configuration of the BRI that you attaching this dialer
too?
Make sure the physical interface has the same ppp configuration ie
encapsulation ppp
ppp multilink links minimum 2
Simon
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Schulz, Dave
Sent: 02 September 2005 17:31
To: ccielab@groupstudy.com
Subject: Second B-channel on ISDN
I am having an issue with getting the second B-channel to initiate dialing
in
the following configuration. The first one dials, so I know the
authentication
and the physical is correct. Any thoughts on what may be missing?
interface Dialer15
bandwidth 128
ip address 10.11.15.1 255.255.255.252
encapsulation ppp
dialer pool 1
dialer remote-name Remote
dialer string 9104490020 class pri
dialer string 9104490021 class pri
dialer load-threshold 1 either
dialer-group 1
no cdp enable
ppp authentication chap
ppp multilink links minimum 2
no clns route-cache
Dave
This archive was generated by hypermail 2.1.4 : Sun Oct 02 2005 - 14:40:13 GMT-3