From: Schulz, Dave (DSchulz@dpsciences.com)
Date: Fri Sep 02 2005 - 13:40:47 GMT-3
Always bringing up the lines based on the minimum links
Dave Schulz, CCDP, CCNP, CCSP
Project Manager / TAC Supervisor
Data Processing Sciences Corporation
10810 Kenwood Road
Cincinnati, Ohio 45242
Phone - (513) 791-7100 ext.7411
Fax - (513) 791-4676
Email: dschulz@dpsciences.com
-----Original Message-----
From: James Matrisciano [mailto:jmatrisciano@kenttech.com]
Sent: Friday, September 02, 2005 12:32 PM
To: Schulz, Dave; ccielab@groupstudy.com
Subject: RE: Second B-channel on ISDN
Threasholds and/or round robin?
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Schulz, Dave
Sent: Friday, September 02, 2005 12:31 PM
To: ccielab@groupstudy.com
Subject: Second B-channel on ISDN
I am having an issue with getting the second B-channel to initiate
dialing in the following configuration. The first one dials, so I know
the authentication and the physical is correct. Any thoughts on what
may be missing?
interface Dialer15
bandwidth 128
ip address 10.11.15.1 255.255.255.252
encapsulation ppp
dialer pool 1
dialer remote-name Remote
dialer string 9104490020 class pri
dialer string 9104490021 class pri
dialer load-threshold 1 either
dialer-group 1
no cdp enable
ppp authentication chap
ppp multilink links minimum 2
no clns route-cache
Dave
This archive was generated by hypermail 2.1.4 : Sun Oct 02 2005 - 14:40:13 GMT-3