From: vidhya natarajan (vidhyanatarajan@rediffmail.com)
Date: Sun Jul 03 2005 - 07:12:39 GMT-3
Hi,
Use the command sh diagostic result mod <> for this.. it shud give
some info on what test failed.... U can also try the command "diagnostic test
module 5 start".. AFAIW, the 2nd command is disruptive.. so make sure u can
take down time bfore starting the test..
HTH...
Thanks,
Vidhya
On Fri, 01
Jul 2005 Kumar Raja-Q16843 wrote :
>Hi All,
>
>I have a alarm reporting from
one of the modules in my catalyst 6509, I don't seem to get more information
on highlighted area, would sincerely appreciate any help.
>
>
>Cat_6509#sh mod
>Mod Ports Card Type Model Serial
No.
>--- ----- -------------------------------------- ------------------
-----------
> 1 2 Cat 6k sup 1 Enhanced QoS (Active)
WS-X6K-SUP1A-2GE SAL06489CTT
> 2 2 Cat 6k sup 1 Enhanced QoS (Standby)
WS-X6K-SUP1A-2GE SAL0732J576
> 4 48 48 port 10/100 mb RJ45
WS-X6348-RJ-45 SAL0741N1H5
> 5 16 16 port GE RJ45
WS-X6316-GE-TX SAD0747010A
>
>Mod MAC addresses Hw
Fw Sw Status
>--- ----------------------------------
------ ------------ ------------ -------
> 1 0009.b7e7.a054 to
0009.b7e7.a055 7.4 5.4(2) 7.5(0.6)HUB1 Ok
> 2 000d.bd3c.19d4 to
000d.bd3c.19d5 7.4 5.4(2) 7.5(0.6)HUB1 Ok
> 4 000d.edb5.fe18 to
000d.edb5.fe47 7.4 5.4(2) 7.5(0.6)HUB1 Ok
> 5 000d.6551.3ce2 to
000d.6551.3cf1 1.3 5.4(2) 7.5(0.6)HUB1 MinFail
>
>Mod Sub-Module
Model Serial Hw Status
>---
--------------------------- --------------- --------------- ------- -------
>
1 Policy Feature Card WS-F6K-PFC SAL06489DEA 2.0 Ok
> 1
Cat6k MSFC 2 daughterboard WS-F6K-MSFC2 SAL06489DP7 2.5 Ok
> 2
Policy Feature Card WS-F6K-PFC SAL0731HNP9 2.0 Ok
> 2
Cat6k MSFC 2 daughterboard WS-F6K-MSFC2 SAL0731J0KZ 2.5 Ok
>
>
>Thanks and regards,
>Raja
>
>_______________________________________________________________________
>Subscription information may be found at:
>http://www.groupstudy.com/list/CCIELab.html
This archive was generated by hypermail 2.1.4 : Sun Sep 04 2005 - 17:00:29 GMT-3