RE: 0% on ISDN

From: ccie2be (ccie2be@nyc.rr.com)
Date: Sun Jun 12 2005 - 17:49:29 GMT-3


There are 2 potential solutions - you already mentioned one - dialer watch.

The other is configure the backup int command on a sub-interface with only
one dlci - if that pvc goes down, backup it will kick in.

HTH, Tim

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of san
Sent: Sunday, June 12, 2005 4:24 PM
To: Danshtr
Cc: Qahtani, Mohammed S.(ECC); Cisco certification
Subject: Re: 0% on ISDN

Danshtr,

quote####
 Maybe you where using a backup interface on a physical interface with
> many DLCI? (The physical line will remain up even if all DLCI are
> down, so the backup interface will never be activated)
######

How do we solve this problem then ? we should use a dialer-watch is it ?

/SAN

On 6/12/05, Danshtr <danshtr@gmail.com> wrote:
> Maybe you where using a backup interface on a physical interface with
> many DLCI? (The physical line will remain up even if all DLCI are
> down, so the backup interface will never be activated)
>
> I fell for that trap once, the next time I knew better...(I think)
>
> On 6/12/05, Qahtani, Mohammed S.(ECC) <mohammed.qahtani.7@aramco.com>
wrote:
> > Hello,
> >
> > Why most people get 0% on the ISDN part of the lab exam. I thought my
> > ISDN configuration was 100% correct but I got 0%. Any clue?
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > Thank you,
> >
> > _______________________________________________________________________
> > Subscription information may be found at:
> > http://www.groupstudy.com/list/CCIELab.html
> >
>
>
> --
> Best regards,
> Dan
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html



This archive was generated by hypermail 2.1.4 : Wed Jul 06 2005 - 14:43:41 GMT-3