RE: IE WB2: How to test Backup Interface?

From: simon hart (simon.hart@btinternet.com)
Date: Sun Apr 10 2005 - 05:47:39 GMT-3


Not tested it, but how about running end to end keepalives on the pvc, then
shutting the physical interface?

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Danshtr
Sent: 10 April 2005 07:31
To: san
Cc: Cisco certification
Subject: Re: IE WB2: How to test Backup Interface?

Also setting the encoding to NRZI will do the job

On Apr 9, 2005 9:19 PM, san <san.study@gmail.com> wrote:
> Hi all,
>
> I have configured ISDN call back between R4 & R5. ISDN callback as
> such is working. Configured as backup for R5's serial
> 0/0.1point-to-point frame-relay interface.
>
> If i shut the serial interface (p2p) i dont see ISDN goes out of
> standby mode. Solution Note also says, shutting primary interface
> does not trigger backup interface to be up up mode.
>
> Is there any other way to test this.?
>
> Thanks
> SAN
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>

--
Best regards,
Dan