From: Matthew Seppeler (Matt.Seppeler@InetX.com)
Date: Sat Nov 06 2004 - 23:12:20 GMT-3
You have your switch interface ports that R1, R2, R6, and BB2 connect to
set to dynamic. The "show isdn status" command will show these ports as
going between a trunk and access port. Set them to access mode with the
"switchport mode access" command and this should solve the issue.
-----Original Message-----
From: Narcis Micsoniu [mailto:micsoniu@telus.net]
Sent: Saturday, November 06, 2004 7:57 PM
To: ccielab@groupstudy.com
Subject: STP issue - bridging over Frame Relay
Internetwork Expert Lab 16 - Task 2.5 - 2.7
I think have an issue with STP:
R1 - E0/0 connected to SW1-Fa0/1 (VLAN16)
R2 - E0/0 connected to SW1-Fa0/2 (VLAN22)
Also, by using trunking:
R6 - Fa1/0.16 <-> SW1- Fa0/6 (VLAN 16)
And
BB2 - <-> SW1- Fa0/24 (VLAN 22)
As soon as the bridge comes up over the FR link, you cannot ping R6 from
R1
and BB1 from R2 (and vice-versa).
I have looked at the STP status and SW1's FastEthernet ports connected
to R1
and R2 are in blocking mode....
Did anybody experience something similar ?
Thank you
Narcis
[GroupStudy removed an attachment of type application/ms-tnef which had
a name of winmail.dat]