From: Cristian Henry H (chenry@reuna.cl)
Date: Tue Oct 19 2004 - 18:15:46 GMT-3
Any problem with the configuration revision number?, what is the rule
about that to keep this double vtp server scenario working well?. What
would I do to add/remove/modify any VLAN in the domain?
Thanks
Brian McGahan ha escrito:
>
> Christian,
>
> Yes, simply configure another VTP server in the network.
> However, if there is only one server and it fails, this does not
> invalidate the information in the VTP database. It simply prevents
> changes being made to the domain unless another device is configured in
> server mode.
>
> HTH,
>
> Brian McGahan, CCIE #8593
> bmcgahan@internetworkexpert.com
>
> Internetwork Expert, Inc.
> http://www.InternetworkExpert.com
> Toll Free: 877-224-8987 x 705
> Outside US: 775-826-4344 x 705
> 24/7 Support: http://forum.internetworkexpert.com
> Live Chat: http://www.internetworkexpert.com/chat/
>
> > -----Original Message-----
> > From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf
> Of
> > Cristian Henry H
> > Sent: Tuesday, October 19, 2004 3:58 PM
> > Cc: ccielab@groupstudy.com
> > Subject: VTP server backup
> >
> > Hi guys,
> >
> > Are there any way to config a VTP server backup scenario?. I mean, if
> a
> > vtp server switch goes down then automatcally another switch can
> operate
> > as the VTP server for the vtp domain.
> >
> > Thanks
> >
> > --
> > Cristian E. Henry
> > REUNA
> >
> > E-mail: chenry@reuna.cl
> > Fono: 56-2-3370336
> >
> >
> _______________________________________________________________________
> > Subscription information may be found at:
> > http://www.groupstudy.com/list/CCIELab.html
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
-- Cristian E. Henry REUNAE-mail: chenry@reuna.cl Fono: 56-2-3370336
This archive was generated by hypermail 2.1.4 : Sat Nov 06 2004 - 17:11:50 GMT-3