From: Moreau, Franck (franck.moreau@amecspie.com)
Date: Mon Jun 28 2004 - 04:11:51 GMT-3
Hi Richard,
I think you can configure bpduguard on your differents ports.
Here is the config with Cat:
#module 3 : 48-port Inline Power Module
set vlan 81 3/1-48
set port auxiliaryvlan 3/2 80
set port auxiliaryvlan 3/3 80
set port auxiliaryvlan 3/4 80
set port auxiliaryvlan 3/5 80
set port auxiliaryvlan 3/6 80
set port auxiliaryvlan 3/7 80
set port auxiliaryvlan 3/8 80
set port auxiliaryvlan 3/9 80
set port auxiliaryvlan 3/10 80
set port auxiliaryvlan 3/11 80
set port auxiliaryvlan 3/12 80
set port auxiliaryvlan 3/13 80
set port auxiliaryvlan 3/14 80
set port auxiliaryvlan 3/15 80
set port auxiliaryvlan 3/16 80
set port auxiliaryvlan 3/17 80
set port auxiliaryvlan 3/18 80
set port auxiliaryvlan 3/19 80
set port auxiliaryvlan 3/20 80
set port auxiliaryvlan 3/21 80
set port auxiliaryvlan 3/22 80
set port auxiliaryvlan 3/23 80
set port auxiliaryvlan 3/24 80
set port auxiliaryvlan 3/25 80
set port auxiliaryvlan 3/26 80
set port auxiliaryvlan 3/27 80
set port auxiliaryvlan 3/28 80
set port auxiliaryvlan 3/29 80
set port auxiliaryvlan 3/30 80
set port auxiliaryvlan 3/31 80
set port auxiliaryvlan 3/32 80
set port auxiliaryvlan 3/33 80
set port auxiliaryvlan 3/34 80
set port auxiliaryvlan 3/35 80
set port auxiliaryvlan 3/36 80
set port auxiliaryvlan 3/37 80
set port auxiliaryvlan 3/38 80
set port auxiliaryvlan 3/39 80
set port auxiliaryvlan 3/40 80
set port auxiliaryvlan 3/41 80
set port auxiliaryvlan 3/42 80
set port auxiliaryvlan 3/43 80
set port auxiliaryvlan 3/44 80
set port auxiliaryvlan 3/45 80
set port auxiliaryvlan 3/46 80
set port auxiliaryvlan 3/47 80
set port auxiliaryvlan 3/48 80
set trunk 3/1 off dot1q 1-1005
set trunk 3/2 off dot1q 1-1005
set trunk 3/3 off dot1q 1-1005
set trunk 3/4 off dot1q 1-1005
set trunk 3/5 off dot1q 1-1005
set trunk 3/6 off dot1q 1-1005
set trunk 3/7 off dot1q 1-1005
set trunk 3/8 off dot1q 1-1005
set trunk 3/9 off dot1q 1-1005
set trunk 3/10 off dot1q 1-1005
set trunk 3/11 off dot1q 1-1005
set trunk 3/12 off dot1q 1-1005
set trunk 3/13 off dot1q 1-1005
set trunk 3/14 off dot1q 1-1005
set trunk 3/15 off dot1q 1-1005
set trunk 3/16 off dot1q 1-1005
set trunk 3/17 off dot1q 1-1005
set trunk 3/18 off dot1q 1-1005
set trunk 3/19 off dot1q 1-1005
set trunk 3/20 off dot1q 1-1005
set trunk 3/21 off dot1q 1-1005
set trunk 3/22 off dot1q 1-1005
set trunk 3/23 off dot1q 1-1005
set trunk 3/24 off dot1q 1-1005
set trunk 3/25 off dot1q 1-1005
set trunk 3/26 off dot1q 1-1005
set trunk 3/27 off dot1q 1-1005
set trunk 3/28 off dot1q 1-1005
set trunk 3/29 off dot1q 1-1005
set trunk 3/30 off dot1q 1-1005
set trunk 3/31 off dot1q 1-1005
set trunk 3/32 off dot1q 1-1005
set trunk 3/33 off dot1q 1-1005
set trunk 3/34 off dot1q 1-1005
set trunk 3/35 off dot1q 1-1005
set trunk 3/36 off dot1q 1-1005
set trunk 3/37 off dot1q 1-1005
set trunk 3/38 off dot1q 1-1005
set trunk 3/39 off dot1q 1-1005
set trunk 3/40 off dot1q 1-1005
set trunk 3/41 off dot1q 1-1005
set trunk 3/42 off dot1q 1-1005
set trunk 3/43 off dot1q 1-1005
set trunk 3/44 off dot1q 1-1005
set trunk 3/45 off dot1q 1-1005
set trunk 3/46 off dot1q 1-1005
set trunk 3/47 off dot1q 1-1005
set trunk 3/48 off dot1q 1-1005
set spantree portfast 3/1-48 enable
set port channel 3/1-48 mode off
Regards
Franck
> -----Message d'origine-----
> De : nobody@groupstudy.com@SPIE De la part de"Richard Anderson"
> <richard.p.anderson@sbcglobal.net>
> Envoyi : dimanche 27 juin 2004 19:37
> @ : ccielab@groupstudy.com
> Objet : Data Voice VLAN
>
>
> Interface FastEthernet0/3
> switchport trunk encapsulation dot1q
> switchport mode trunk
> switchport access vlan 1 -----------------------Default
> switchport voice vlan 31
> no ip address
> mls qos trust cos
> spanning-tree portfast
>
> The spanning-tree port-fast command enabled automatically, I beleive
> because
> of the voice vlan configuration. What I like to know if it is necessary
> to
> configure "Spanning-tree bpduguard" command to put the port in err-disable
> mode if someone connects a switch to the other end instead of the host. I
> have done that for Data only configuration, but do I need to do that where
> both voice/data vlans are configured on the same port, and PC will be
> connected to the IP Phone. Please advise.
>
>
> Can someone help configuring the same commands with CAT-OS as it doesn't
> have
> a such command "Switchport voice vlan x" instead it requires "Auxilary
> Port"
> command. I did search on CCO, but I am not very clear about it.
>
> Regards,
>
> Richard
>
> _______________________________________________________________________
> Please help support GroupStudy by purchasing your study materials from:
> http://shop.groupstudy.com
>
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
This archive was generated by hypermail 2.1.4 : Sat Jul 03 2004 - 19:40:51 GMT-3