RE: PPP Multilink question

From: CHIONG, ERWIN R (ASI) (ec2929@sbc.com)
Date: Thu Sep 04 2003 - 15:04:23 GMT-3


Hello Robert,

Using the default HDLC encapsulation would bring both lines up immediately,
but if you are using PPP encapsulation, then 'ppp multilink load-threshold
1' would be best method (CCIE Practical Studies vol1, page 300).

Regards,
-Erwin

-----Original Message-----
From: Roberts, Larry [mailto:Larry.Roberts@expanets.com]
Sent: Thursday, September 04, 2003 10:53 AM
To: Ccielab Mailing List (ccielab@groupstudy.com)
Subject: PPP Multilink question

I'm working on some practice labs and the requirement is to automatically
bring up 2 BRI channels when connected.

Now, I see 2 ways of doing this.

1) ppp multilink link minimum 2

2) ppp multilink load-threshold 1

Any thoughts one which is the "best" way, or correct way?

Thanks

Larry



This archive was generated by hypermail 2.1.4 : Wed Oct 01 2003 - 07:24:23 GMT-3