From: miken (miken@sisna.com)
Date: Tue May 20 2003 - 17:20:50 GMT-3
John,
This is how I have things set up on my term server and using Secure CRT or
Windows telnet with a window open to each router at the same time.
Applicable router config:
line 1 16 (would be 1 8 for 2509)
no exec
exec-timeout 0 0
transport input all
With Secure CRT or Windows telnet, telnet to the 2509's IP address and
rather than using the standard port 23, use port 2001, 2002, 2003, 2004, etc
up to 2008. You can change the port during the initial connection or going
to properties of the connection later. Do a show line on your 2509 and
you'll see the tty lines are being used rather than vty lines.
I like to do all of my labs this way and the real thing. It takes some
getting used the smaller windows, so it is good to practice doing it this
way. You can't believe the things you see when you are watching all your
routers at the same time running debug ip routing. Head it off at the pass
so to speak.
HTH,
Mike N.
----- Original Message -----
From: "Bigelow, John" <John.Bigelow@bcbsfl.com>
To: "'Brian Dennis'" <brian@labforge.com>; <ccielab@groupstudy.com>
Sent: Tuesday, May 20, 2003 12:51 PM
Subject: RE: Secure CRT
> I was assuming that there was a way to use the reverse telnet and
> the crt program so that I can have 8 short cuts that will allow me to
open
> all 8 sessions simultaneously....Watching both sides of any debug or
> connection is the best way to trouble shoot and really learn what is
> happening. Not to mention making sure that when configuring opposite sides
> of a connection that you are properly mirroring them. I will try Adams
idea
> and if I continue to have a brain lock I will ask more.
> Thanks,
>
> John B Bigelow CCIE #10565 MCSE
> Network Analyst II
> Enterprise Deployment
> John.Bigelow@BCBSFL.com
> x - 904-363-5401
> NAS-161
>
>
> -----Original Message-----
> From: Brian Dennis [mailto:brian@labforge.com]
> Sent: Tuesday, May 20, 2003 1:25 PM
> To: Bigelow, John; ccielab@groupstudy.com
> Subject: RE: Secure CRT
>
>
> Can you clarify this a little more "cannot figure out how to use it with
> my 2509"?
>
> Also it's a good decision to keep your lab after you get your CCIE. For
> some people the CCIE is the end of their journey and for others it's
> just the beginning. ;-)
>
> Brian Dennis, CCIE #2210 (R&S/ISP-Dial/Security)
>
>
> -----Original Message-----
> From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
> Bigelow, John
> Sent: Tuesday, May 20, 2003 9:16 AM
> To: ccielab@groupstudy.com
> Subject: Secure CRT
>
> Does anyone know how to set up Secure CRT (the program used at
> RTC
> for viewing multiple router sessions) I have kept my lab and wish to
> make it
> more convenient to view things I am testing. I have a copy but cannot
> figure
> out how to use it with my 2509.
> Thanks,
>
> John B Bigelow CCIE #10565 MCSE
> Network Analyst II
> Enterprise Deployment
> John.Bigelow@BCBSFL.com
> x - 904-363-5401
> NAS-161
>
>
>
> Blue Cross Blue Shield of Florida, Inc., and its subsidiary and
> affiliate companies are not responsible for errors or omissions in this
> e-mail message. Any personal comments made in this e-mail do not reflect
> the views of Blue Cross Blue Shield of Florida, Inc. The information
> contained in this document may be confidential and intended solely for
> the use of the individual or entity to whom it is addressed. This
> document may contain material that is privileged or protected from
> disclosure under applicable law. If you are not the intended recipient
> or the individual responsible for delivering to the intended recipient,
> please (1) be advised that any use, dissemination, forwarding, or
> copying of this document IS STRICTLY PROHIBITED; and (2) notify sender
> immediately by telephone and destroy the document. THANK YOU.
>
>
>
> Blue Cross Blue Shield of Florida, Inc., and its subsidiary and affiliate
companies are not responsible for errors or omissions in this e-mail
message. Any personal comments made in this e-mail do not reflect the views
of Blue Cross Blue Shield of Florida, Inc. The information contained in
this document may be confidential and intended solely for the use of the
individual or entity to whom it is addressed. This document may contain
material that is privileged or protected from disclosure under applicable
law. If you are not the intended recipient or the individual responsible
for delivering to the intended recipient, please (1) be advised that any
use, dissemination, forwarding, or copying of this document IS STRICTLY
PROHIBITED; and (2) notify sender immediately by telephone and destroy the
document. THANK YOU.
This archive was generated by hypermail 2.1.4 : Mon Jun 02 2003 - 15:13:45 GMT-3