From: balaji.balakrishnan (balaji.balakrishnan@swift.com)
Date: Fri Apr 25 2003 - 17:05:33 GMT-3
All,
I never saw an Ethernet interface saying down / down . If the link is not working or cable is unplugged, ususally it will be UP
/ down. But see this,
Any idea ? The switch is 2950G.
interface FastEthernet0/8
switchport access vlan 22
switchport mode access
no ip address
duplex full
speed 100
no cdp enable
end
R1#sh int FastEthernet0/8
FastEthernet0/8 is down, line protocol is down
Hardware is Fast Ethernet, address is 0009.e822.5908 (bia 0009.e822.5908)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Full-duplex, 100Mb/s
input flow-control is off, output flow-control is off
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output 7w2d, output hang never
Last clearing of "show interface" counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue :0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
1 packets input, 64 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 input packets with dribble condition detected
1 packets output, 64 bytes, 0 underruns
[GroupStudy removed an attachment of type application/x-pkcs7-signature which had a name of smime.p7s]