Re: About CBWFQ

From: Donny MATEO (donny.mateo@sg.ca-indosuez.com)
Date: Thu Apr 03 2003 - 06:41:03 GMT-3


Hi ,

normally the command bandwidth percent would use the bandwidth command as a reference. However, for frame-relay this does not apply. For frame-relay the minCIR is the value used as a reference for bandwidht-percent command. if minCIR is not defined the
default is to 1/2 of the CIR.

Hope that helps.
Donny

                                                                                                                                       
                      "Re-act"
                      <wantingfeng@hotm To: <ccielab@groupstudy.com>
                      ail.com> cc:
                      Sent by: Subject: About CBWFQ
                      nobody@groupstudy
                      .com
                                                                                                                                       
                                                                                                                                       
                      18-01-2003 10:21
                      Please respond to
                      "Re-act"
                                                                                                                                       
                                                                                                                                       

Hi,group
  I have a question about translate CQ to CBWFQ.when using CBWFQ,what difference between the command bandwidth XXX and bandwidth percent ZZ?and if I use "bandwidth percent",must I use a reference bandwidth on the interface and change max-band with 100%?
  and if i use "bandwidth",must I use the two commands? thanks

This message is for information purposes only and its content
should not be construed as an offer, or solicitation of an offer,
to buy or sell any banking or financial instruments or services
and no representation or warranty is given in respect of its
accuracy, completeness or fairness. The material is subject
to change without notice. You should take your own independent
tax, legal and other professional advice in respect of the content
of this message. This message may contain confidential or
legally privileged material and may not be copied, redistributed
or published (in whole or in part) without our prior written consent.
This email may have been intercepted, partially destroyed,
arrive late, incomplete or contain viruses and no liability is
accepted by any member of the Credit Agricole Indosuez group
as a result. If you are not the intended recipient of this message,
please immediately notify the sender and delete this message
from your computer.



This archive was generated by hypermail 2.1.4 : Thu May 01 2003 - 13:35:46 GMT-3