RE: Frame-Relay question

From: Khalid A. Kaseb (khalid_ameen@rayaintegration.com)
Date: Mon Feb 24 2003 - 06:24:16 GMT-3


Have a look in your frame-relay switch configuration and check the show
frame route on it to check the proper dlci configured on your switch

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Alsontra Daniels
Sent: Monday, February 24, 2003 1:29 AM
To: ccielab@groupstudy.com
Subject: Frame-Relay question

I have a not so interesting problem with a fairly common frame-relay
config.
I'm working on LAB13 out of the CCIE practical studies book. (second or
third time I've done this one) Every no an again I run into a problem
with a
specific dlci not coming up or going into active state.

Config is as follows: A single HUB router with two interfaces. The first
is
multipoint and the second is point to point.
After the initial router configurations, I reboot the HUB and all spokes
to
fix any arp issues. All interfaces are ping-able except the interface
behind
dlci 120. HUB config is below-

(HUB Router config)
interface Serial0.1 multipoint
 ip address 10.10.1.9 255.255.255.248
 no ip route-cache
 no ip mroute-cache
 frame-relay map ip 10.10.1.10 110 broadcast
 frame-relay map ip 10.10.1.11 120 broadcast
!
interface Serial0.2 point-to-point
 ip address 192.168.1.5 255.255.255.252
 no ip route-cache
 no ip mroute-cache
 frame-relay interface-dlci 130

After checking the configs, I am sure that all configs are correct, but
dlci
remains inactive. dlci 120 is inactive on the adjacent switch as well.
Have
I missed a curial gotcha?

(output of sh frame pvc for dlci 120)

DLCI = 120, DLCI USAGE = LOCAL, PVC STATUS = INACTIVE, INTERFACE =
Serial0.1

  input pkts 0 output pkts 3 in bytes 0
  out bytes 141 dropped pkts 0 in FECN pkts 0
  in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
  in DE pkts 0 out DE pkts 0
  out bcast pkts 3 out bcast bytes 141
  pvc create time 00:18:25, last time pvc status changed 00:15:20

(Output of sh frame pvc on the adjacent switch)

DLCI = 120, DLCI USAGE = SWITCHED, PVC STATUS = INACTIVE, INTERFACE =
Serial0

  input pkts 13 output pkts 0 in bytes 643
  out bytes 0 (WHY)--> dropped pkts 179 in FECN pkts 0
  in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
  in DE pkts 0 out DE pkts 0
  out bcast pkts 0 out bcast bytes 0
  pvc create time 01:33:28, last time pvc status changed 00:51:44
  Num Pkts Switched 4

Thanks in advance!!

al alsontra@panix.com



This archive was generated by hypermail 2.1.4 : Sat Mar 01 2003 - 11:06:33 GMT-3