Re: Frame-Relay PVC/interface go down

From: MADMAN (dave@interprise.com)
Date: Tue Sep 03 2002 - 14:31:33 GMT-3


  Yes this is a good thing!! If the interface went down then every PVC
would be affected. Since 11.1 you will see the individual PVC status.
If you configure your frame with p-p subinterfaces the subinterface will
go down. Why would you want the physical interface to go down because
of one remote link??

  Dave

pbeleznay@bcn.hu wrote:
>
> Hi Group!
>
> A short question...
> In Frame-Relay enviroment if the PVC goes down, the main interface is still
> up. OK, it's a good thing, but I would like to achive that if this
> situation happens, the interface is go to down too. How can I achive this?
> I've heard about end-to-end keepalive feature, but the documentation
> doesn't mention anything about the interface's condition (and I've tried,
> but haven't worked). Any idea (maybe working config...)?
>
> Thanks:
> Peter

-- 
David Madland
CCIE# 2016
Sr. Network Engineer
Qwest Communications
612-664-3367

"You don't make the poor richer by making the rich poorer." --Winston Churchill



This archive was generated by hypermail 2.1.4 : Mon Oct 07 2002 - 07:43:42 GMT-3