From: Sharif ow (sharifow@xxxxxxxxxxx)
Date: Thu Aug 08 2002 - 16:34:45 GMT-3
Did you set clock rate on DCE side?
Thanks,
Sharifow
>From: Sam.MicroGate@usa.telekom.de
>Reply-To: Sam.MicroGate@usa.telekom.de
>To: DAGOMEISTER@prodigy.net, ccielab@groupstudy.com
>Subject: RE: Funny Serial problem
>Date: Mon, 5 Aug 2002 14:44:08 -0400
>
>line is up because there is no physical problem with either the physical
>port or the cable. The line protocol is up because it receives keepalive
>messages from its ppp peer even it has different mask.
>
>Sam
>
>-----Original Message-----
>From: Sam Dagoski [mailto:DAGOMEISTER@prodigy.net]
>Sent: Monday, August 05, 2002 3:31 PM
>To: ccielab@groupstudy.com
>Subject: Funny Serial problem
>
>
>How come this does not work:
>
>Router 1:
>inter s0
> ip address 200.20.1.129 255.255.255.240
> encap ppp
>
>Router 2:
>inter s0
> ip address 200.20.1.130 255.255.255.224
> encap ppp
>
>The masks are different. If the masks are different
>on a serial connection, the two sides will not be
>able to ping each other -- even thought the line is
>up and line protocol is up.
>
>Any ideas?
>
>---------------------------------------------------------
>Sam Dagoski
>Priciple Engineer
This archive was generated by hypermail 2.1.4 : Sat Sep 07 2002 - 19:48:21 GMT-3