Re: Ring numbers in SRB

From: Fred Ingham (fingham@xxxxxxx)
Date: Mon Jul 08 2002 - 23:41:13 GMT-3


   
Jan:
1. This is normal behavior for the switch. Two TrCRF's assigned to the
same TrBRF cannot have the same ring number.

2. If you have two routers on the same ring assign both router ports to the
same TrCRF. Why do you configure a second TrCRF?

Cheers, Fred

----- Original Message -----
From: "John White" <jan_white7@hotmail.com>
To: <harish.dv@peakxv.net>
Cc: <ccielab@groupstudy.com>
Sent: Monday, July 08, 2002 5:04 PM
Subject: Re: Ring numbers in SRB

> I'm not sure if I make myself clear. I assigned the same TrBRF and 2
> diffrent TrCRFs to 2 rotuters,and then I tried to assing the same ring
> number to TrCRFs, when I got en error message saying that ring # has been
> already allocated.
> So the questions is -Was I doing something wrong or this is normal
behaviour
> for switch. What am I driving at is if we have diagram with 2 routers
> attached to the same ring(lets say 200), does it mean we need actually 2
> different # 200 and 201 to implement this on the TR Switch.?
> Jan
> clipped <<



This archive was generated by hypermail 2.1.4 : Sat Sep 07 2002 - 19:36:22 GMT-3