From: hramosr@xxxxxxx
Date: Sun Mar 17 2002 - 20:59:29 GMT-3
Hi,
Do someone hat experience with Token Ring catalyst 1800 and can help me how
to get frames in, or how to activate the ports?
The physical ports are apparently active (the port state from display looks
as enable), but looking the monitor statistics the ports do not get some
frames, broadcast, ..., the TR-interface from router is connected wit a cat5
cable + TR-media-filter both are o.k.
No ports in the catalyst get some frames, the switch works with defaults
parameters
When the router try to activate the interface, the connection fails to open.
debug Token events
01:17:13: TR0 starting.
01:17:14: TR0 receive SRB_FREE, state=2, if_state=6
01:17:15: %TR-3-OPENFAIL: Unit 0, open failed: Lobe Test, failed
01:17:15: %TR-3-BADSTART: Unit 0, Start completion and wrong idb state -
state= 0
01:17:16: TR0: reset from 309187E
01:17:16: TR0: txtmr: 0x0, msclk: 0x46BEC0, qt: 0x0 (4636348ms)
thanks
Hector
-- GMX - Die Kommunikationsplattform im Internet. http://www.gmx.net