From: David Siwula (DSiwula@xxxxxxxxxx)
Date: Sat Feb 23 2002 - 01:13:03 GMT-3
You should not configure "no exec" for any line on the terminal server that
you are trying to reverse telnet to.
Dave
-----Original Message-----
From: Steve Schoeneman [mailto:steve@abacast.com]
Sent: Friday, February 22, 2002 6:58 PM
To: ccielab@groupstudy.com
Subject: RE: Catalyst 5000 via 2511
Thanks for all the replies, 'no exec' did the trick. Here are the details:
term_serv(config)#line 1 16
term_serv(config-line)#no exec
term_serv(config-line)#^Z
term_serv#sho line 2
Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise Overruns
* 2 TTY 9600/9600 - - - - - 0 3 9/31
Line 2, Location: "", Type: ""
Length: 24 lines, Width: 80 columns
Baud rate (TX/RX) is 9600/9600, no parity, 2 stopbits, 8 databits
Status: Ready, Active
Capabilities: EXEC Suppressed
Modem state: Ready
Special Chars: Escape Hold Stop Start Disconnect Activation
^^x none - - none
Timeouts: Idle EXEC Idle Session Modem Answer Session Dispatch
0:10:00 never none not set
Session limit is not set.
Time since activation: 0:03:41
Editing is enabled.
History is enabled, history size is 10.
Full user help is disabled
Allowed transports are pad telnet rlogin. Preferred is telnet.
No output characters are padded
No special data dispatching characters
Modem hardware state: CTS noDSR DTR RTS
term_serv#cat5000
Trying cat5000 (10.0.0.1, 2002)...
% Connection refused by remote host
term_serv#clear line 2
[confirm]
[OK]
term_serv#sho line 2
Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise Overruns
2 TTY 9600/9600 - - - - - 0 24 15/47
Line 2, Location: "", Type: ""
Length: 24 lines, Width: 80 columns
Baud rate (TX/RX) is 9600/9600, no parity, 2 stopbits, 8 databits
Status: Ready
Capabilities: EXEC Suppressed
Modem state: Ready
Special Chars: Escape Hold Stop Start Disconnect Activation
^^x none - - none
Timeouts: Idle EXEC Idle Session Modem Answer Session Dispatch
0:10:00 never none not set
Session limit is not set.
Time since activation: never
Editing is enabled.
History is enabled, history size is 10.
Full user help is disabled
Allowed transports are pad telnet rlogin. Preferred is telnet.
No output characters are padded
No special data dispatching characters
Modem hardware state: CTS noDSR DTR RTS
term_serv#cat5000
Trying cat5000 (10.0.0.1, 2002)... Open
Unknown command "R". Use 'help' for more info.
Console>
-----Original Message-----
From: Erick B. [mailto:erickbe@yahoo.com]
Sent: Friday, February 22, 2002 12:08 PM
To: Steve Schoeneman; ccielab@groupstudy.com
Subject: Re: Catalyst 5000 via 2511
Hi,
Put a 'no exec' under the line for the cat5000.
I'm betting that when you power them on together the
5000 sends signal out its port and the 2511
establishes a connection. If you a 'show line' on the
2511 then clear line 2 that should free up the
connection then you should be able to get to it. The
'no exec' prevents inbound traffic from using the
line.
--- Steve Schoeneman <steve@abacast.com> wrote:
> I have searched the archives and can find nothing
> similar. My problem is
> that if I power up my rack at the same time using
> the power strips, I cannot
> reverse telnet to my Cat 5000 getting a "Connection
> refused" message at the
> 2511 terminal. If I power down both units and power
> up the Cat then the 2511
> while the Cat is coming back up I can sometimes
> connect ok, sometimes not. I
> have never had trouble connecting my PC direct to
> the Cat.
>
> Am I missing something really basic here? Below is
> part of the 2511 config.
>
> Thanks in advance.
>
> Steve
>
> ip host r1 2001 10.0.0.1
> ip host cat5000 2002 10.0.0.1
> ip host cat3900 2003 10.0.0.1
> ip host r2 2005 10.0.0.1
> ip host r3 2006 10.0.0.1
> ip host r4 2008 10.0.0.1
> ip host r6 2007 10.0.0.1
> ip host r7 2009 10.0.0.1
>
> line con 0
> transport input none
> line 1
> modem Host
> transport input all
> line 2
> transport input all
> line 3 16
> modem Host
> transport input all
>