From: Mannan Venkatesan (mv_lab@xxxxxxxxxxx)
Date: Wed Feb 06 2002 - 05:58:56 GMT-3
I tried to use FR end-to-end keepalive on a multipoint interface and when I
shut the remote interfaces, the PVC status changes to inactive but the line
protocol stays 'up'. So, I couldn't test 'backup interface' command. Anybody
tried this before?
Mannan
----- Original Message -----
From: "Mannan Venkatesan" <mv_lab@hotmail.com>
To: "Antonio Marfil" <tony.marfil@networxcorp.com>; <ccielab@groupstudy.com>
Sent: Wednesday, February 06, 2002 3:48 AM
Subject: Re: How to test a BRI backup int?
> If it is ppp/hdlc encap., shut the remote router's interface. It also
works
> with FR P-t-P sub-if.
>
> Mannan
>
> ----- Original Message -----
> From: "Antonio Marfil" <tony.marfil@networxcorp.com>
> To: <ccielab@groupstudy.com>
> Sent: Wednesday, February 06, 2002 3:12 AM
> Subject: How to test a BRI backup int?
>
>
> > is there any way to test a backup int without physically disconnecting
the
> > serial int that you are trying to backup? shutting down a serial
> interface
> > for example, when the backup int is a bri doesn't do the trick, but
> pulling
> > the cable from the serial int does (automatically brings up the bri
int.)
> >
> > thanks,
> > tony
This archive was generated by hypermail 2.1.4 : Thu Jun 20 2002 - 13:46:12 GMT-3