From: tom cheung (tkc9789@xxxxxxxxxxx)
Date: Wed Dec 26 2001 - 13:20:33 GMT-3
Steve,
Yes, you're correct also. By default PVCs are assigned to the physical
interface and mapping is not needed.
Tom
>From: "Stephen C. Feldberg" <scfeldberg@hotmail.com>
>To: "tom cheung" <tkc9789@hotmail.com>, <tonyblair@etang.com>,
><ccielab@groupstudy.com>
>Subject: Re: frame relay pvc inactive
>Date: Wed, 26 Dec 2001 10:43:27 -0500
>
>Tom,
>
>You are right, the config for the frame switch is correct - I did not read
>all of the configs. However, since physical interfaces are present on both
>sides of the frame switch, FR mapping or FR intrerface-dlci is not required
>to bring up the PVC. If you recall your FR theory, PVCs (by default) are
>assigned to the physical interfaces connected to the frame switch. You
>would
>use maps or interface-dlci to reassign them to a logical subinterface.
>
>Wen jia,
>
>I'm thinking it's a physical layer problem now. Look at the physical and
>FR
>state of the S0 interfaces on RouterA and Frame switch. Look for the
>interface and/or line protocol to be in a down state.
>
>r1#sh controllers serial 0
>HD unit 0, idb = 0xD557C, driver structure at 0xDA9F0
>buffer size 1524 HD unit 0, V.35 DTE cable <<<<<<<<<<<<<
>cpb = 0x22, eda = 0x2814, cda = 0x2828
>
>Show controlers for the serial 0 interfaces to make sure that the end that
>you have assigned the clock rate to is indeed the DCE - it is possible to
>assign clock rate to a DTE interface before the interface is enabled.
>
>Steve
>----- Original Message -----
>From: "tom cheung" <tkc9789@hotmail.com>
>To: <scfeldberg@hotmail.com>; <tonyblair@etang.com>;
><ccielab@groupstudy.com>
>Sent: Wednesday, December 26, 2001 10:21 AM
>Subject: Re: frame relay pvc inactive
>
>
> > wen jia yang,
> > Config for the frame switch is fine. You need to add the following to
>serial0 for both routerA and routerB:
> >
> > frame-relay interface-dlci xxx, where xxx is 200 for routerA and 210 for
>routerB.
> >
> > HTH
> >
> > Tom
> >
> > >From: "Stephen C. Feldberg" <scfeldberg@hotmail.com>
> > >Reply-To: "Stephen C. Feldberg" <scfeldberg@hotmail.com>
> > >To: "wen jia yang" <tonyblair@etang.com>, <ccielab@groupstudy.com>
> > >Subject: Re: frame relay pvc inactive
> > >Date: Wed, 26 Dec 2001 09:47:28 -0500
> > >
> > >interface Serial0
> > > no ip address
> > > no ip directed-broadcast
> > > encapsulation frame-relay
> > > no ip mroute-cache
> > >no ip mroute-cache
> > > clockrate 64000
> > > cdp enable
> > > frame-relay lmi-type ansi
> > > frame-relay intf-type dce <<<<<<<<<<<<<<<<
> > > frame-relay route 200 interface Serial1 210
> > >!
> > >interface Serial1
> > > no ip address
> > > no ip directed-broadcast
> > > encapsulation frame-relay
> > > clockrate 64000
> > > cdp enable
> > > frame-relay lmi-type ansi
> > > frame-relay intf-type dce <<<<<<<<<<<<<<<<<<
> > > frame-relay route 210 interface Serial0 200
> > >
> > >
> > >Although S0 and S1 are both DCE at the physical layer, only one side of
>the
> > >FR connection can be frame-relay interface-type DCE. Removing the
>statement
> > >from either serial interface will resolve your problem.
> > >
> > >Steve
> > >----- Original Message -----
> > >From: "wen jia yang" <tonyblair@etang.com>
> > >To: <ccielab@groupstudy.com>
> > >Sent: Monday, December 24, 2001 9:03 PM
> > >Subject: frame relay pvc inactive
> > >
> > >
> > > > RouterA s0------s0 FrameSwitch s1------s0 RouterB
> > > > dlci 200 dlci210
> > > >
> > > > The following are the configs:
> > >
> >
>--------------------------------------------------------------------------
> > >----------------------------------
> > > > Current configuration:
> > > > !
> > > > version 12.0
> > > > service timestamps debug uptime
> > > > service timestamps log uptime
> > > > no service password-encryption
> > > > !
> > > > hostname FrameSwitch
> > > > !
> > > > !
> > > > ip subnet-zero
> > > > frame-relay switching
> > > > !
> > > > !
> > > > !
> > > > !
> > > > !
> > > > interface Serial0
> > > > no ip address
> > > > no ip directed-broadcast
> > > > encapsulation frame-relay
> > > > no ip mroute-cache
> > > > no ip mroute-cache
> > > > clockrate 64000
> > > > cdp enable
> > > > frame-relay lmi-type ansi
> > > > frame-relay intf-type dce
> > > > frame-relay route 200 interface Serial1 210
> > > > !
> > > > interface Serial1
> > > > no ip address
> > > > no ip directed-broadcast
> > > > encapsulation frame-relay
> > > > clockrate 64000
> > > > cdp enable
> > > > frame-relay lmi-type ansi
> > > > frame-relay intf-type dce
> > > > frame-relay route 210 interface Serial0 200
> > > > !
> > > > interface Serial2
> > > > no ip address
> > > > no ip directed-broadcast
> > > > encapsulation frame-relay
> > > > clockrate 64000
> > > > cdp enable
> > > > frame-relay lmi-type ansi
> > > > .
> > > > .
> > > > .
> > > > line con 0
> > > > exec-timeout 0 0
> > > > transport input none
> > > > line aux 0
> > > > line vty 0 4
> > > > no login
> > > > !
> > > > end
> > >
> >
>--------------------------------------------------------------------------
> > >--------------------------------
> > > > Current configuration:
> > > > !
> > > > version 12.0
> > > > service timestamps debug uptime
> > > > service timestamps log uptime
> > > > no service password-encryption
> > > > service tcp-small-servers
> > > > !
> > > > hostname RouterA
> > > > !
> > > > !
> > > > ip subnet-zero
> > > > no ip domain-lookup
> > > > !
> > > > !
> > > > !
> > > > !
> > > > !
> > > > interface Ethernet0
> > > > no ip address
> > > > no ip directed-broadcast
> > > > no ip route-cache
> > > > interface Serial0
> > > > ip address 192.1.1.1 255.255.255.0
> > > > no ip directed-broadcast
> > > > encapsulation frame-relay
> > > > no ip route-cache
> > > > no ip mroute-cache
> > > > frame-relay lmi-type ansi
> > > > !
> > > > interface Serial1
> > > > no ip address
> > > > no ip directed-broadcast
> > > > no ip route-cache
> > > > no ip mroute-cache
> > > > clockrate 64000
> > > > !
> > > > interface TokenRing0
> > > > no ip address
> > > > no ip directed-broadcast
> > > > no ip route-cache
> > > > no ip mroute-cache
> > > > shutdown
> > > > router rip
> > > > network 192.1.1.0
> > > > network 193.1.1.0
> > > > !
> > > > ip nat translation timeout never
> > > > ip nat translation tcp-timeout never
> > > > ip nat translation udp-timeout never
> > > > ip nat translation finrst-timeout never
> > > > ip nat translation syn-timeout never
> > > > ip nat translation dns-timeout never
> > > > ip nat translation icmp-timeout never
> > > > no ip classless
> > > > !
> > > > !
> > > > !
> > > > line con 0
> > > > exec-timeout 0 0
> > > > transport input none
> > > > line aux 0
> > > > transport input all
> > > > line vty 0 4
> > > > no login
> > > > !
> > > > end
> > >
> >
>--------------------------------------------------------------------------
> > >----------------------------------
> > > > Current configuration:
> > > > !
> > > > version 12.0
> > > > service timestamps debug uptime
> > > > service timestamps log uptime
> > > > no service password-encryption
> > > > !
> > > > hostname RouterB
> > > > !
> > > > !
> > > > ip subnet-zero
> > > > no ip domain-lookup
> > > > frame-relay de-list 3 protocol ip gt 512
> > > > !
> > > > !
> > > > !
> > > > !
> > > > !
> > > > interface Ethernet0
> > > > no ip address
> > > > no ip directed-broadcast
> > > > !interface Serial0
> > > > ip address 192.1.1.2 255.255.255.0
> > > > no ip directed-broadcast
> > > > encapsulation frame-relay
> > > > no ip mroute-cache
> > > > frame-relay lmi-type ansi
> > > > !
> > > > interface Serial1
> > > > no ip address
> > > > no ip directed-broadcast
> > > > clockrate 64000
> > > > !
> > > > router rip
> > > > network 192.1.1.0
> > > > !
> > > > ip nat translation timeout never
> > > > ip nat translation tcp-timeout never
> > > > ip nat translation udp-timeout never
> > > > ip nat translation finrst-timeout never
> > > > ip nat translation syn-timeout never
> > > > ip nat translation dns-timeout never
> > > > ip nat translation icmp-timeout never
> > > > no ip classless
> > > > !
> > > > !
> > > > !
> > > > line con 0
> > > > exec-timeout 0 0
> > > > transport input none
> > > > line aux 0
> > > > exec-timeout 0 0
> > > > line vty 0 4
> > > > exec-timeout 0 0
> > > > no login
> > > > !
> > > > end
> > >
> >
>--------------------------------------------------------------------------
> > >----------------------------------
> > > > RouterA#sh frame pvc
> > > >
> > > > PVC Statistics for interface Serial0 (Frame Relay DTE)
> > > >
> > > > DLCI = 200, DLCI USAGE = LOCAL, PVC STATUS = INACTIVE, INTERFACE =
>Serial0
> > > >
> > > > input pkts 65 output pkts 43 in bytes 8334
> > > > out bytes 2382 dropped pkts 3 in FECN pkts 0
> > > > in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
> > > > in DE pkts 0 out DE pkts 0
> > > > out bcast pkts 43 out bcast bytes 2382
> > > > pvc create time 00:20:44, last time pvc status changed 00:19:35
> > > >
> > > > FrameSwitch#sh frame pvc
> > > >
> > > > PVC Statistics for interface Serial0 (Frame Relay DCE)
> > > >
> > > > DLCI = 200, DLCI USAGE = SWITCHED, PVC STATUS = INACTIVE, INTERFACE
>=
> > >Serial0
> > > >
> > > > input pkts 47 output pkts 70 in bytes 2606
> > > > out bytes 9066 dropped pkts 0 in FECN pkts 0
> > > > in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
> > > > in DE pkts 0 out DE pkts 0
> > > > out bcast pkts 23 out bcast bytes 6486 Num Pkts
>Switched
> > >47
> > > >
> > > > pvc create time 00:22:30, last time pvc status changed 00:22:20
> > > >
> > > > PVC Statistics for interface Serial1 (Frame Relay DCE)
> > > >
> > > > DLCI = 210, DLCI USAGE = SWITCHED, PVC STATUS = ACTIVE, INTERFACE =
> > >Serial1
> > > >
> > > > input pkts 47 output pkts 70 in bytes 2580
> > > > out bytes 9092 dropped pkts 0 in FECN pkts 0
> > > > in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
> > > > in DE pkts 0 out DE pkts 0
> > > > out bcast pkts 23 out bcast bytes 6486 Num Pkts
>Switched
> > >47
> > > >
> > > > pvc create time 00:22:29, last time pvc status changed 00:22:19
> > > > PVC Statistics for interface Serial2 (Frame Relay DCE)
> > > >
> > > >
> > > > the dlci 200 pvc in always inactive,I check the frame switch but
>found
>no
> > >error there.all the encaps and lmi-types are match,anyone offer a hand?
> > > > Thanks in Advance.
> > > >
> > > > Frankly speaking this is where I met in the lab in some training
> > >centers,but when I move the identical config into my home lab,it
>works,all
> > >the pvcs are active,can anyone tell what the problem is?
This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:32:47 GMT-3