FREEK - Why doesn't it declare the serial 0 line down with these settings ?

From: Padhu (LFG) (padhu@xxxxxxxxxxxx)
Date: Mon Aug 06 2001 - 15:07:40 GMT-3


   
I have the below config on all my hub and spoke routers and when i remove
the pvc on the frame switch going between the hub and spokes, show frame pvc
shows deleted however the serial line is still up up everywhere.
According to the docs it should declare the line down after error threshold
has reached. The pvcs were in deleted for about 30 mins still no luck. I
thought i that was the purpose of Freek. End to end monitor and declare line
down if keepalives fail.

Any insights ?

Cheers,Padhu

map-class frame-relay ccie
 frame-relay end-to-end keepalive mode bidirectional
 frame-relay end-to-end keepalive event-window send 10
 frame-relay end-to-end keepalive event-window recv 10
 frame-relay end-to-end keepalive error-threshold send 5
 frame-relay end-to-end keepalive error-threshold recv 5
 frame-relay end-to-end keepalive success-events send 5
 frame-relay end-to-end keepalive success-events recv 5

interface Serial0.2 multipoint
 bandwidth 256
 ip ospf hello-interval 5
 ip ospf priority 255
 frame-relay class ccie

================================================================
Padhu
Phone : 312-368-3239
Asst Vice President,Technology Development Fax :
312-602-4330
Liberty Funds Group
Email : padhu@steinroe.com
1 South Wacker Drive ,31st Floor URL
: www.steinroe.com
Chicago, IL-60606.
=================================================================
**Please read:http://www.groupstudy.com/list/posting.html



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:31:46 GMT-3