Solve the problem? It sounds more like mask the problem. 'Carrier-delay
20' will cause the interface to wait 20 seconds after carrier loss to
report a link-down event (the default is 2 seconds). In the long-run, I
would think it would be in your best interests for your carrier to fix
the root cause of the problem, rather than have you mask it.
Mas
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
JUAN FAURE FERRER
Sent: Thursday, June 14, 2001 7:44 AM
To: ccielab@groupstudy.com
Subject: Carrier-delay command
Hello!
I've having problems providing service to my client by means of a Frame
Relay, because there is very frecuent lost of carrier. Then the serial
line goes down for a few seconds only, but sometimes the PVCs go down
too.
The frame relay provider says that I must put in the serial interface
the command "carrier-delay 20" to solve theses problems.
Do yo know that command and what does it exactly?
Thank you very much and best regards
Juan Faure Ferrer
e-mail: jfaure@ipt.es
Area de Telematica
Integracisn de Redes y Sistemas
IPT SOLUZIONA TELECOMUNICACIONES
c/Jerez, 3 28016 MADRID