From: Doug Hammond (dhammond@xxxxxxxxx)
Date: Wed May 02 2001 - 18:10:45 GMT-3
I have two routers with token ring interfaces connected to a common ring (ring
3) via a token-ring switch. As long as I stick to ip, everything is fine I can
ping or whatever. When I put srb on it though, it works for about 5-10 minutes
and then I get a message on the switch that says:
Port 1 disabled (Ring number mismatch detected)
Port 3 disabled (Ring number mismatch detected)
And everything is hosed. I have tried almost every combination of the
source-bridge bridge-number token-ring-number target-ring-number with no joy.
Any ideas?
Here are my configs:
R1
source-bridge ring-group 100
dlsw local-peer peer-id 170.150.3.1
interface TokenRing0
ip address 170.150.11.1 255.255.255.0
ring-speed 4
multiring all
source-bridge 3 1 100
R3
source-bridge ring-group 100
dlsw local-peer peer-id 170.150.1.1
interface TokenRing0
ip address 170.150.11.3 255.255.255.0
ring-speed 4
multiring all
source-bridge 3 1 100
On the Token switch I have:
TrBRF/TrCRF ID Brdg/Rng Ports
-----------------------------------------------------------------
brf100 100 0x01
crf3 3 A-0x03 yes
trbrf-default 1005 0x0F
trcrf-default 1003 0x01 yes
and:
Port Mode TrCRF TrBRF
1 Static crf3 brf100
2 Static trcrf-default trbrf-default
3 Static crf3 brf100
4 Static trcrf-default trbrf-default