From: Foster, Kristopher (KFoster@xxxxxxxxxxxxxxxxxxxx)
Date: Fri Apr 20 2001 - 10:56:36 GMT-3
There shouldn't be any problem with this. In a number of situations two
switches are connected via two trunk ports for physical redundancy (STP
being used to block one of the ports).
Kris,
-----Original Message-----
From: Tariq Sharif [mailto:tariq_sharif@btinternet.com]
Sent: April 20, 2001 9:40 AM
To: Ccielab@Groupstudy. Com
Subject: STP on Cat 5Ks
Hi all,
I wanted to practice STP & trunking on Cat5ks. At the moment I get my hands
on 2 (5002). Could you tell me if it is possible to do STP & trunks by
having 2 connections between the 2 switches? I know ideally I need 3 to get
STP going but may be I can get some practice with 2?
Many thanks & regards.
Tariq Sharif
[GroupStudy.com removed an attachment of type application/ms-tnef which had
a name of winmail.dat]
**Please read:http://www.groupstudy.com/list/posting.html
**Please read:http://www.groupstudy.com/list/posting.html
This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:29:52 GMT-3