From: Greg Ferro (gferro@xxxxxxxxxxxxxxxxxxx)
Date: Sat Jan 20 2001 - 02:15:07 GMT-3
Here is how I configure my LS100 and some of the outputs. I have 6 or 7 ATM
interfaces so I configured them anyway. Was useful when LANE was a part of
it, since I have 5 LANE modules. Now they are just a pile on my desk.
Enjoy.
Greg
These lines set the VPI to be 0 bits long, and VCI 12 bits.
#set inter 2 0 0 0 12
Line Interface 2 has been registered.
A100#set inter 4 0 0 0 12
Line Interface 4 has been registered.
A100#set inter 6 0 0 0 12
Line Interface 6 has been registered.
A100#set inter 8 0 0 0 12
Line Interface 8 has been registered.
A100#set inter 10 0 0 0 12
Line Interface 10 has been registered.
A100#set inter 12 0 0 0 12
Line Interface 12 has been registered.
These lines set up the PVC's on each interface for a full mesh.
pvc est 1 2 2 0 204 512 0 155 4 0 402 512 0 155
pvc est 1 2 2 0 206 512 0 155 6 0 602 512 0 155
pvc est 1 2 2 0 208 512 0 155 8 0 802 512 0 155
pvc est 1 2 2 0 210 512 0 155 10 0 1002 512 0 155
pvc est 1 2 2 0 212 512 0 155 12 0 1202 512 0 155
pvc est 1 2 4 0 406 512 0 155 6 0 604 512 0 155
pvc est 1 2 4 0 408 512 0 155 8 0 804 512 0 155
pvc est 1 2 4 0 410 512 0 155 10 0 1004 512 0 155
pvc est 1 2 4 0 412 512 0 155 12 0 1204 512 0 155
pvc est 1 2 6 0 608 512 0 155 8 0 806 512 0 155
pvc est 1 2 6 0 610 512 0 155 10 0 1006 512 0 155
pvc est 1 2 6 0 612 512 0 155 12 0 1206 512 0 155
pvc est 1 2 8 0 810 512 0 155 10 0 1008 512 0 155
pvc est 1 2 8 0 812 512 0 155 12 0 1012 512 0 155
pvc est 1 2 10 0 1012 512 0 155 12 0 1210 512 0 155
A100#pvc est 1 2 2 0 204 512 0 155 4 0 402 512 0 155
***Connection has been established.
Connection Type : Bi
Traffic Type : UBR-BE
Low Throughput : -
High Throughput : -
LowLine LowVPI LowVCI LowUP LowCO HiLine HiVPI HiVCI HiUP HiCO
2 0 204 512 Pass 4 0 402 512 Pass
A100#show pvc 2
Bandwidth Available (Forward/Backward/Line Rate): 155.0 / 155.0 / 155.0 Mbps
Existing connections : 0 (Uni), 1 (Bi), 0 (Multipoint), 2 (Gateway)
LowLine LowVPI LowVCI HiLine HiVPI HiVCI TrfType CONNECTION
2 0 5 16 0 2 UBR-BE Gateway
2 0 16 16 0 3 UBR-BE Gateway
2 0 204 4 0 402 UBR-BE Bi
A100#show pvc 4
Bandwidth Available (Forward/Backward/Line Rate): 155.0 / 155.0 / 155.0 Mbps
Existing connections : 0 (Uni), 1 (Bi), 0 (Multipoint), 2 (Gateway)
LowLine LowVPI LowVCI HiLine HiVPI HiVCI TrfType CONNECTION
4 0 5 16 0 2 UBR-BE Gateway
4 0 16 16 0 3 UBR-BE Gateway
4 0 402 2 0 204 UBR-BE Bi
At 12:01 AM 20/01/2001 -0500, Curtis Phillips wrote:
>Documentation for the LS100 being scant and cryptic at best, I wonder if
>anyone has an idea how to set the interface parameters on the LS100 to
>allow the correct number of VPI and VCI bits.. Apparently this is the
>problem as I am unable to get the thing to register with the router
>anything in VPI 0. I would assume on the primary interface. I am further
>unable to get the switch to allow me to configure a pvc with a vpi of 1 or
>more. Any information would be appreciated.
>
> Curtis
><erik@pinnacleinc.com> wrote:
> >
> > yes
> >
> > -----Original Message-----
> > From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
> > Curtis Phillips
> > Sent: Friday, January 19, 2001 5:02 PM
> > To: ccielab@groupstudy.com
> > Subject: PVC discovery on an LS100
> >
> >
> > Hello,
> >
> > Does nayone know if the LS100 will work with a router to support ilmi pvc
> > discovery?
> >
> > Thanks in advance,
> >
> > Curtis
This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:27:36 GMT-3