Bob,
Have you changed the boot buffersize.... This may help.
This will allow you to get it loaded, then you can use the
compress-config command.
Haven't done this in a while. I'll look into this if it doesn't work
for you.
Dave
goss-a1-5300(config)#boot buffersize ?
<0-4294967295> Buffer size
Bob Harrison wrote:
> We have a problem with a really large config that will
> not fit into NVRAM (don't even get me started :)) I
> know there is a way we can copy the config into flash
> and have already done that. The problem is what do we
> need to change in the reg or the config so that the
> router would boot its config file from flash in case
> of an unintended reload? I have tried:
> copy running-config flash
>
> works and the file shows in show flash. Then I set the
> boot system flash:running-config command. Reload and
> it doesn't work. Is there an additional registry
> setting that we need to set to make it work? Platform
> is 5300.
>