RE: Token Ring router

From: Yurchenko, Michael (michael.yurchenko@xxxxxxxxxxx)
Date: Wed Jan 17 2001 - 13:56:37 GMT-3


   
That would be a physical problem with the ring. Check the ring speeds to
match, try different ports on the MAU. Also, some passive MAUs apparently
have problem when there's only one device attached to them.

-----Original Message-----
From: McCallum, Robert [mailto:Robert.McCallum@let-it-be-thus.com]
Sent: Wednesday, January 17, 2001 11:47 AM
To: 'Ccielab' (E-mail)
Subject: Token Ring router

Hello,

Trying to configure up a lab at the moment. I am running into severe
difficulty when trying to connect two routers via a token ring interface.

Scenario = R1 ---token ring0/0(ip 148.100.150.1/24) ---- MAU ----token
ring0/0(ip 148.100.150.2/24) ----R2.

I am getting all sorts of ring errors i.e. need to wait for new
monitor.%TR-3-OPENFAIL: Unit 0, open failed: phase4, ring beaconing

Whether I configure source bridge ring numbers makes no difference.

Has anyone done this before who can point me to a link or in the right
direction. Try not to tell me the answer right out.

Cheers

Robert McCallum



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:27:32 GMT-3