RE: strange request - back to back aux ports

From: Simon Baxter (Simon.Baxter@xxxxxxxxxxxxxx)
Date: Thu Aug 24 2000 - 21:52:19 GMT-3


   
   Don't you hate that?
   
   I've had exactly the same experience with Frame in-arp, Lane and (of
   course) appletalk in the last 3 days!!!
   
   -----Original Message-----
   From: David [mailto:d.ankers@cable.a2000.nl]
   Sent: Friday, August 25, 2000 10:52 AM
   To: ccielab@groupstudy.com
   Subject: Re: strange request - back to back aux ports
   
   Damn, it actually worked the way I configured it, just that it took
   about 10 mins to come up. Went for a coffee, came back it was up / up.
   Anyway, here's the configs, is there anything missing or not required?
   
   
   
   R1
   
   
   
   interface Async1
    ip address 10.1.2.1 255.255.255.252
    encapsulation ppp
    keepalive 10
    async mode dedicated
   
   
   
   line aux 0
    modem InOut
    rotary 1
    transport input all
    stopbits 1
    rxspeed 38400
    txspeed 38400
    flowcontrol hardware
   
   
   
   R2 is exactly the same only the IPs are obviously different.
   
   
   
   Regards,
   
   
   
   David
   
   
   
   ----- Original Message -----
   
   From: David
   
   To: ccielab@groupstudy.com
   
   Sent: Friday, August 25, 2000 2:39 AM
   
   Subject: strange request - back to back aux ports
   
   Group,
   
   
   
   I know that it should be possible to link two 2500 routers via their
   AUX ports with PPP, anyone know how this is done? I guess a rollover
   console cable should work, is this correct?
   
   
   
   Regards,
   
   
   
   David
   
   



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 08:24:29 GMT-3