RE: 6500 IOmem

From: Joseph L. Brunner <joe_at_affirmedsystems.com>
Date: Fri, 23 Aug 2013 22:33:08 +0000

No hardware QOS only

Are you studying or configuring a production network?

-----Original Message-----
From: nobody_at_groupstudy.com [mailto:nobody_at_groupstudy.com] On Behalf Of Dave Serra
Sent: Friday, August 23, 2013 5:52 PM
To: group-study
Subject: 6500 IOmem

Hi Guys. I've been studying QoS and am confused on something. Does the 6500 use an IOMem in DRAM for packet buffers? I've been trying to figure out if the 6500 can do any type of traffic shaping on Ethernet cards (not TDM) and it looks like a big NO. Then I started investigating to find that smaller platforms do the shaping in DRAM using IOMem. Now when I issue the command "show region" on my sup720 I do see IOMem is there but what is it used for? I know that packets are switched/routed in the ASICs on the PFC and DFC if available but wouldn't process switched packets hit IOMem?
 
If you have
read this far I owe you a big Thank You :)

Make a small loan, Make a big
difference - Kiva.org

Blogs and organic groups at http://www.ccie.net
Received on Fri Aug 23 2013 - 22:33:08 ART