7200 can have only one NPE. There is no redundancy for the Network
Processing Engines, regardless of the model (7204, 7206, VXR/non-VXR).
The slot in front, even though it looks like it will take an NPE is
for I/O modules, which are not used/recommended with NPE-G1/G2 cards,
but were required with older generation NPEs (225, 300, 400).
-- Marko Milivojevic - CCIE #18427 (SP R&S) Senior CCIE Instructor / Managing Partner - IPexpert On Wed, Feb 6, 2013 at 5:40 AM, M Adnan <taurusadnan19_at_gmail.com> wrote: > Hello to all group members > > i have cisco 7206vxr with single NPEG1 is in runing on it.but 7206vxr have > multiple slots for NPE G1.. > > i need a advise can i install multiple NPE G1 module on 7206vxr slot is > already present ??? > > also want to know after installation multiple NPE G1 module both NPEG1 > module work sepratly or ACTIVE standby mode??? > > > Thank in advance > > Muhammad Adnan > > > Blogs and organic groups at http://www.ccie.net > > _______________________________________________________________________ > Subscription information may be found at: > http://www.groupstudy.com/list/CCIELab.html Blogs and organic groups at http://www.ccie.netReceived on Wed Feb 06 2013 - 08:56:46 ART
This archive was generated by hypermail 2.2.0 : Fri Mar 01 2013 - 07:57:58 ART