OT 3750-X

From: Tony Singh <mothafungla_at_gmail.com>
Date: Sun, 18 Nov 2012 19:00:25 +0000

Hi sorry for OT

But I don't understand if say we have two switches connected via the two ASIC data cables on the rear which as I understand would support 16gbps each to fully sync data forwarding in case of failure etc

If the two switch members have fully populated switch ports going to devices I.e all 24 ports on master switch populated and all 24 ports on member populated then when failure occurs, then how would forwarding on either switch handle the others fully populated switch ports considering its own are already populated.

I may be confused

I understand this would happen as follows i.e when a stack member is added I can see g2/0/1 etc formed so would it be a case that these are the replicas of the switch member and traffic continues to be forwarded via the ASIC interface bi-directionally and cable at the rear?

--
BR
Tony
Sent from my iPhone on 3
Blogs and organic groups at http://www.ccie.net
Received on Sun Nov 18 2012 - 19:00:25 ART

This archive was generated by hypermail 2.2.0 : Sat Dec 01 2012 - 07:27:50 ART