Re: VSS query-Access switch connecting two VSS domain

From: Joe Sanchez <marco207p_at_gmail.com>
Date: Wed, 10 Oct 2012 20:25:00 -0500

No. The VSL would need to communicate between the domain members within the same domain number to identify packet flow.

Regards,
 Joe Sanchez

( please excuse the brevity of this email as it was sent via a mobile device. Please excuse misspelled words or sentence structure.)

On Oct 10, 2012, at 7:42 PM, Shahid Ansari <shahid1357_at_gmail.com> wrote:

> Hi group,
> Is it possible to form LAG etherchannel by connecting two uplink of single
> access switch to two different VSS domain?
> Whereas Two VSS domains are connected each other by LAG.
> My answer is NO .LAG will not form.
> I have notice some diagram on cisco website in which Access switches are
> connecting to two different VSS domain with no technical explanation.
> Your output plz
>
> Thanks
> SHAHID
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net
Received on Wed Oct 10 2012 - 20:25:00 ART