Hi guys,
I have this doubt if someone can clarify..
I usually don't remember the severity levels so I always do a logging
monitor ? to make sure to see the correct match between numbers and names:
R1(config)#logging monitor ?
<0-7> Logging severity level
alerts Immediate action needed (severity=1)
critical Critical conditions (severity=2)
debugging Debugging messages (severity=7)
discriminator Establish MD-Console association
emergencies System is unusable (severity=0)
errors Error conditions (severity=3)
filtered Enable filtered logging
informational Informational messages (severity=6)
notifications Normal but significant conditions (severity=5)
warnings Warning conditions (severity=4)
xml Enable logging in XML
ok, now If I am asked to log all events up to errors, am I correct If I do
a 'logging facility local 3' ?
if I'm asked to log all events up to notifications am I correct if I do a
'logging facility local 5' ?
checking the master index I see this:
logging facility facility-type Argument
local0-7
Reserved for locally defined messages
thanks for your help.
-- @ccie99999 Blogs and organic groups at http://www.ccie.netReceived on Thu Oct 04 2012 - 04:16:13 ART