Re: disable terminal monitor

From: Mohamed A. Abbas <m.abdelmonsef_at_gmail.com>
Date: Sat, 12 May 2012 13:50:10 +0200

yes,

conf t
loggin monitor 0
will take the severity 0 which disables every thing
after that check the show log

example:

R1#terminal monitor
R1#no term moni ?
% Unrecognized command
R1#conf t
Enter configuration commands, one per line. End with CNTL/Z.
R1(config)#loggin moni ?
  <0-7> Logging severity level
  alerts Immediate action needed (severity=1)
  critical Critical conditions (severity=2)
  debugging Debugging messages (severity=7)
  discriminator Establish MD-Console association
  emergencies System is unusable (severity=0)
  errors Error conditions (severity=3)
  filtered Enable filtered logging
  informational Informational messages (severity=6)
  notifications Normal but significant conditions (severity=5)
  warnings Warning conditions (severity=4)
  xml Enable logging in XML
  <cr>

R1(config)#loggin moni 0 ?
  <cr>

Aswan-TEDATA-R1(config)#loggin moni 0
Aswan-TEDATA-R1(config)#do sh log
Syslog logging: enabled (12 messages dropped, 1 messages rate-limited,
                0 flushes, 0 overruns, xml disabled, filtering disabled)

No Active Message Discriminator.

No Inactive Message Discriminator.

    Console logging: level debugging, 29 messages logged, xml disabled,
                     filtering disabled
    Monitor logging: *level emergencies*, 0 messages logged, xml disabled,
                     filtering disabled
        Logging to: vty514(0)
    Buffer logging: level warnings, 4 messages logged, xml disabled,
                     filtering disabled
    Logging Exception size (4096 bytes)
    Count and timestamp logging messages: disabled
    Persistent logging: disabled

No active filter modules.

ESM: 0 messages dropped

    Trap logging: level informational, 33 message lines logged

Log Buffer (51200 bytes):

*Jan 2 09:07:23.555: %LINK-3-UPDOWN: Interface FastEthernet0/0, changed
state to up
*Jan 2 09:07:23.555: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed
state to up
*Jan 2 09:07:23.555: %LINK-3-UPDOWN: Interface Serial0/0/0, changed state
to up
*Jan 2 09:07:23.555: %LINK-3-UPDOWN: Interface Serial0/0/1, changed state
to up
Aswan-TEDATA-R1(config)#

On Sat, May 12, 2012 at 1:42 PM, amin <amin_at_axizo.com> wrote:

> Hi expert,
>
> Can I disable terminal monitor without exit from the line?
>
> Regards,
>
> Amin
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>

--
*
--
 Eng. Mohamed A. Monsef
Cisco Networks Engineer
CCNP. - CCIP. - CCDP.
CS-RSSS. - ITIL.
ISO/IEC 27002.
Cell Phone : +2 010 677 2 887
Land Line : +2 02 267 42 453
*
Blogs and organic groups at http://www.ccie.net
Received on Sat May 12 2012 - 13:50:10 ART