To explain clearly.
trunks are configured between sw1 to sw2, sw3 and sw4.
sw1 is in transparent mode
sw2 is in server mode
sw3 and sw4 are in client mode
Once I changed sw1 to transparent md5 on sw1 doesn't match to that on sw2.
Also, since sw2 is server mode, when I created a vlan it supposed to
propagate to other switches in client mode that is sw3 and sw4. But, I
don't see that happening when sw1 is in transparent mode.
SW1#sh vtp status
VTP Version : 2
Configuration Revision : 0
Maximum VLANs supported locally : 1005
Number of existing VLANs : 11
VTP Operating Mode : Transparent
VTP Domain Name : CCIE
VTP Pruning Mode : Disabled
VTP V2 Mode : Enabled
VTP Traps Generation : Disabled
MD5 digest : 0xC4 0x17 0x67 0xE6 0xB0 0x6D 0xF0 0x38
Configuration last modified by 155.30.37.7 at 3-2-93 18:09:58
SW1#
SW1#sh vlan id 126
VLAN id 126 not found in current VLAN database
SW1#conf t
Enter configuration commands, one per line. End with CNTL/Z.
SW1(config)#vtp vers
SW1(config)#vtp version 2
VTP mode already in V2.
SW1(config)#
===
SW2(config)#vl 126
SW2(config-vlan)#
SW2#
SW2#
SW2#
SW2#
SW2#
1d18h: %SYS-5-CONFIG_I: Configured from console by console
SW2#sh vl id 126
VLAN Name Status Ports
---- -------------------------------- ---------
-------------------------------
126 VLAN0126 active Fa0/13, Fa0/14, Fa0/15
VLAN Type SAID MTU Parent RingNo BridgeNo Stp BrdgMode Trans1
Trans2
---- ----- ---------- ----- ------ ------ -------- ---- -------- ------
------
126 enet 100126 1500 - - - - - 0 0
Remote SPAN VLAN
----------------
Disabled
Primary Secondary Type Ports
------- --------- -----------------
------------------------------------------
SW2#
SW2#sh vtp status
VTP Version : 2
Configuration Revision : 6
Maximum VLANs supported locally : 1005
Number of existing VLANs : 19
VTP Operating Mode : Server
VTP Domain Name : CCIE
VTP Pruning Mode : Disabled
VTP V2 Mode : Enabled
VTP Traps Generation : Disabled
MD5 digest : 0xA0 0x68 0x07 0x2C 0xB9 0xF2 0xFA 0x6B
Configuration last modified by 155.30.8.8 at 3-2-93 18:12:06
Local updater ID is 155.30.8.8 on interface Vl8 (lowest numbered VLAN
interface found)
SW2#
SW2#
SW2#
====
SW4# sh vl | i ^126
SW4#sh vl id 126
VLAN id 126 not found in current VLAN database
SW4#sh vtp status
VTP Version : 2
Configuration Revision : 5
Maximum VLANs supported locally : 1005
Number of existing VLANs : 18
VTP Operating Mode : Client
VTP Domain Name : CCIE
VTP Pruning Mode : Disabled
VTP V2 Mode : Enabled
VTP Traps Generation : Disabled
MD5 digest : 0xF5 0xDB 0xB5 0xDC 0x36 0xF8 0xF3 0x30
Configuration last modified by 155.30.8.8 at 3-2-93 18:09:58
Thanks,
Karthik.
On Wed, Mar 14, 2012 at 10:31 PM, karthik thatikonda
<get2explore_at_gmail.com>wrote:
> Hi,
>
> When configuring sw2 as transparent mode, seeing that md5 is not matched
> on the switches and any creation of vlan on sw1 i.e. server is not
> propagation vtp updates to sw3 and sw4. If I change sw2 to client, md5
> shows correct on all switches and sw3 and sw4 learn vlan created on sw2
> (server). Am I missing anything?. Please, let me know.
>
> SW2#sh vtp status
> VTP Version : 2
> Configuration Revision : 4
> Maximum VLANs supported locally : 1005
> Number of existing VLANs : 18
> VTP Operating Mode : Server >>>>>>>>>>>>>>>>>>>>>>>
> VTP Domain Name : CCIE
> VTP Pruning Mode : Disabled
> VTP V2 Mode : Disabled
> VTP Traps Generation : Disabled
> MD5 digest : 0x3C 0xAF 0xD7 0xFB 0xB5 0x11 0xB4 0x4B
> >>>>>>>>>>>>>>>>>>
> Configuration last modified by 155.30.8.8 at 3-2-93 05:38:01
> Local updater ID is 155.30.8.8 on interface Vl8 (lowest numbered VLAN
> interface found)
> SW2#
> SW2#
>
>
>
> SW1#sh vtp status
> VTP Version : 2
> Configuration Revision : 0
> Maximum VLANs supported locally : 1005
> Number of existing VLANs : 11
> VTP Operating Mode : Transparent >>>>>>>>>>>>>>>>>>>>>>>>>>>>>
> VTP Domain Name : CCIE
> VTP Pruning Mode : Disabled
> VTP V2 Mode : Disabled
> VTP Traps Generation : Disabled
> MD5 digest : 0x9B 0x27 0x73 0x7F 0xB4 0xB1 0xD3 0x29
> ==========>>>>>>>
> Configuration last modified by 155.30.37.7 at 3-2-93 03:10:45
> SW1#conf t
> Enter configuration commands, one per line. End with CNTL/Z.
> SW1(config)#vtp mod clie
> Setting device to VTP CLIENT mode.
> SW1(config)#
>
> +++++
>
> AFter changing to client. md5 matches
>
> +++++
>
>
> SW1#sh vtp status
> VTP Version : 2
> Configuration Revision : 4
> Maximum VLANs supported locally : 1005
> Number of existing VLANs : 18
> VTP Operating Mode : Client
> VTP Domain Name : CCIE
> VTP Pruning Mode : Disabled
> VTP V2 Mode : Disabled
> VTP Traps Generation : Disabled
> MD5 digest : 0x3C 0xAF 0xD7 0xFB 0xB5 0x11 0xB4 0x4B
> Configuration last modified by 155.30.8.8 at 3-2-93 05:38:01
> Thanks,
>
> Karthik.
Blogs and organic groups at http://www.ccie.net
Received on Thu Mar 15 2012 - 10:51:27 ART
This archive was generated by hypermail 2.2.0 : Sun Apr 01 2012 - 07:56:52 ART