Hi George,
Real world issues are prventing this - No ports available on 5K.
Regards
On Tue, Mar 13, 2012 at 5:48 PM, George J. Sanchez <marco207p_at_gmail.com> wrote:
> This is bad juju, you have access switch to access switch. By default the 2k would have bpdu guard on all the edge ports, for our setup to be configured you must have turned on bpdufilter on the 3750 to have it connected to the 2ks at the bottom. Why not connect the 3750 switch directly to the 5ks using a vPC?
>
> Regards,
> Joe Sanchez
>
> On Mar 13, 2012, at 6:53 AM, jack daniels <jckdaniels12_at_gmail.com> wrote:
>
>> Hi Guys,
>>
>> I have a scenario for which I'm scratching my head since long - please help
>>
>>
>> Nexus 5K-1---------Nexus5K-2
>> | |
>> | |
>> Nexus2K-1 Nexus2K-2
>> | | Port eth 1/1
>> | |
>> Cisco 3750-----------------------
>>
>>
>> In this scenario Switching LOOP is getting formed. Only way I'm able
>> to get rid is shutdown Port eth1/1 on Nexus2K-2. Please help in this
>> case.
>>
>> Thanks in anticipation in adavance.
>>
>> Regards
>> Jack
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net
Received on Tue Mar 13 2012 - 18:22:02 ART
This archive was generated by hypermail 2.2.0 : Sun Apr 01 2012 - 07:56:52 ART