Hi...
I work for 2 Company with two Datacenters. On all LWL Ports UDLD mode
Agressive is enabled and never experienced Problems.
Greetings
Martin
2011/9/11 Carlos G Mendioroz <tron_at_huapi.ba.ar>
> Joseph,
> I don't think the physician metaphor applies, or else, you'd rather do the
> IP routing on all the networks by hand ???
> The time it takes for a human to react to an event is HUGE compared to
> an automatic procedure. I guess we all agree on that.
>
> What IMHO is important in your argument is that UDLD is not dependable.
> I have no direct experience to such faults, anyone else care to comment?
>
> -Carlos
>
>
> Joseph L. Brunner @ 11/09/2011 06:01 -0300 dixit:
>
> Surely, in a critical, redundant environment one would configure
>>> aggressive mode instead of normal mode?
>>>
>>
>> No because taking a whole link down is a major event in a production
>> network. Your network should get the alerts to peoples smartphones/screens
>> who can fix the issue and determine if further action is required before
>> taking a link down and re-routing traffic to a different layer 2 path.
>>
>> Also, UDLD is not always very accurate - so you may not want to trust
>> it... I have had it fail on copper many times and think the link was
>> unidirectional, simply because of poor copper links, etc.
>>
>> You're missing the fact the UDLD feature is not as good at detecting an
>> issue as a qualified person responding to an alert...
>>
>> "Would you want UDLD to perform brain surgery on your child or a skilled
>> physician?
>>
>> -Joe
>>
>>
>> -----Original Message-----
>> From: nobody_at_groupstudy.com [mailto:nobody_at_groupstudy.com] On Behalf Of
>> Atle Xrn Hardarson
>> Sent: Saturday, September 10, 2011 9:22 AM
>> To: Ccielab_at_groupstudy.com
>> Subject: UDLD recommendations
>>
>> Hi guys
>>
>> I was reading up on UDLD, and I have always wondered why Cisco recommends
>> normal mode for UDLD, and not aggressive mode?
>> Surely, in a critical, redundant environment one would configure
>> aggressive
>> mode instead of normal mode?
>> Personally, I would much rather see my network loose a link with UDLD
>> shutdown of a port, than causing a potential bridging loop in the entire
>> L2
>> domain.
>>
>> Can anyone shed some light on this? What am I missing?
>>
>> Atle
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> ______________________________**______________________________**
>> ___________
>> Subscription information may be found at: http://www.groupstudy.com/**
>> list/CCIELab.html <http://www.groupstudy.com/list/CCIELab.html>
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> ______________________________**______________________________**
>> ___________
>> Subscription information may be found at: http://www.groupstudy.com/**
>> list/CCIELab.html <http://www.groupstudy.com/list/CCIELab.html>
>>
>>
>>
>>
>>
>>
>>
>>
> --
> Carlos G Mendioroz <tron_at_huapi.ba.ar> LW7 EQI Argentina
>
>
>
> Blogs and organic groups at http://www.ccie.net
>
> ______________________________**______________________________**
> ___________
> Subscription information may be found at: http://www.groupstudy.com/**
> list/CCIELab.html <http://www.groupstudy.com/list/CCIELab.html>
Blogs and organic groups at http://www.ccie.net
Received on Sun Sep 11 2011 - 21:51:55 ART
This archive was generated by hypermail 2.2.0 : Sat Oct 01 2011 - 07:26:25 ART