Can you post a sh controller pos x/x/x
for both of the interfaces on either side?
On Thu, Aug 11, 2011 at 9:36 AM, Persio Pucci <persio_at_gmail.com> wrote:
> Hi all,
>
> anybody with good experience with POS/SDH and some spare time? :)
>
> I am getting some B3 errors on a OC12 circuit I have. The (not) funny thing
> is that when I get the B3 errors, I have input errors and CRC errors
> incremented ON BOTH SIDES of the circuit.
>
> Is this an issue on the SDH transport? Cause I've been researching about it
> and Cisco literature says B3 are path-level errors and most likely to be
> caused by some router interface. If it is a router issue, what can I do to
> resolve it?
>
> Any thoughts?
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net
Received on Thu Aug 11 2011 - 09:46:11 ART
This archive was generated by hypermail 2.2.0 : Thu Sep 01 2011 - 06:05:56 ART