Because one says "I can not be path to root to this neighbour" and the
other says "this neighbour can not be path to the root switch for me".
They are kind of incompatible...
-Carlos
Pablo Bonilla @ 27/05/2011 14:06 -0300 dixit:
> Hi i am looking for answer about the next question.
>
> Why when i activate root guard and loop guard in the same interface the
> switch only remain the the last feature activated??
>
> I know that the operation of this features work in different situations so i
> dont know why only the last one is activated.
>
>
> regards,
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
-- Carlos G Mendioroz <tron_at_huapi.ba.ar> LW7 EQI Argentina Blogs and organic groups at http://www.ccie.netReceived on Fri May 27 2011 - 14:25:10 ART