Re: Internet Traffic load balancing

From: Marko Milivojevic <markom_at_ipexpert.com>
Date: Mon, 2 May 2011 18:39:42 -0700

On Mon, May 2, 2011 at 17:45, Carlos G Mendioroz <tron_at_huapi.ba.ar> wrote:
> This was generated from the switching point ? I.e. it was generated by the
> router having the 5:2 statics ?
>
> I would test it from a neighbour, so CEF is used for sure. Local trafic
> is process switched most probably.

Those are valid points, but are contrary to what was originally
expected. My argument was that CEF would break this, but I honestly
expected that it would work when process-switched. It doesn't seem to.
I will add 3rd router behind R2 and re-run the test.

--
Marko Milivojevic - CCIE #18427
Senior Technical Instructor - IPexpert
FREE CCIE training: http://bit.ly/vLecture
Mailto: markom_at_ipexpert.com
Telephone: +1.810.326.1444
Web: http://www.ipexpert.com/
Blogs and organic groups at http://www.ccie.net
Received on Mon May 02 2011 - 18:39:42 ART

This archive was generated by hypermail 2.2.0 : Wed Jun 01 2011 - 09:01:11 ART