The CAM table aging timer needs to be greater than or equal to the ARP table
aging timer. The common fix is to set the MAC aging time to 14400.
Ronnie
On Mar 2, 2011 9:58 PM, "Gary Lileikis" <gary.lileikis_at_gmail.com> wrote:
Just wondering if anyone has seen this issue and if there are work-around?
Thanks!!!
Gary
Blogs and organic groups at http://www.ccie.net
Received on Wed Mar 02 2011 - 22:18:05 ART