The PVDMs are DSPs. The 2-16 is actually one DSP, the 2-48 has 3 of them.
Now, DSPs are processors that run a program that is loaded at
initialization time. The program is specific for one task, but
there are a few: termination, conference, x-coding.
The problem you are facing is that you are using, I would bet, 2 DSPs
for termination (you have 24 or 30 B channels at the box ?).
So if you only have 2 DSPs (2xPVDM2-16) then both are loaded with
termination code and you have no free DSP for conferencing.
On the other hand, if you have a PVDM2-48, you still have a free
DSP for conference or xcoding. (But not both!)
-Carlos
Tortle Tang @ 05/02/2011 00:14 -0300 dixit:
> Hi Guys
>
> I have 2xPVDM2-16 in 2 slots, but when I configure " dspfarm profile 1
> conference", The max session is only 0. If I replace 2xPVDM2-16 with 1xPVDM2
> 48, I won't have any problem.
>
> Any idea ?
>
>
> R2#sh diag | in PVDM
> PVDM Slot 0:
> 16-channel (G.711) Voice/Fax PVDMII DSP SIMM PVDM daughter card
> Product (FRU) Number : PVDM2-16
> PVDM Slot 1:
> 16-channel (G.711) Voice/Fax PVDMII DSP SIMM PVDM daughter card
> Product (FRU) Number : PVDM2-16
>
>
> voice-card 0
> dsp services dspfarm
>
> R2(config)#dspfarm profile 1 conference
> R2(config-dspfarm-profile)#max
> R2(config-dspfarm-profile)#maximum se
> R2(config-dspfarm-profile)#maximum sessions ?
> <0-0> Number of sessions assigned to this profile
>
> Thanks,
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
-- Carlos G Mendioroz <tron_at_huapi.ba.ar> LW7 EQI Argentina Blogs and organic groups at http://www.ccie.netReceived on Sat Feb 05 2011 - 09:24:20 ART