Re: PVDM2 in voice lab

From: Carl Gosselin <carl.gosselin_at_altizone.com>
Date: Fri, 4 Feb 2011 22:20:48 -0500

Try this...

!
voice-card 0
 dspfarm
 dsp services dspfarm
!

/Carl

On Fri, Feb 4, 2011 at 10:14 PM, Tortle Tang <tortletang_at_hotmail.com> wrote:

> Hi Guys
>
> I have 2xPVDM2-16 in 2 slots, but when I configure " dspfarm profile 1
> conference", The max session is only 0. If I replace 2xPVDM2-16 with
> 1xPVDM2
> 48, I won't have any problem.
>
> Any idea ?
>
>
> R2#sh diag | in PVDM
> PVDM Slot 0:
> 16-channel (G.711) Voice/Fax PVDMII DSP SIMM PVDM daughter card
> Product (FRU) Number : PVDM2-16
> PVDM Slot 1:
> 16-channel (G.711) Voice/Fax PVDMII DSP SIMM PVDM daughter card
> Product (FRU) Number : PVDM2-16
>
>
> voice-card 0
> dsp services dspfarm
>
> R2(config)#dspfarm profile 1 conference
> R2(config-dspfarm-profile)#max
> R2(config-dspfarm-profile)#maximum se
> R2(config-dspfarm-profile)#maximum sessions ?
> <0-0> Number of sessions assigned to this profile
>
> Thanks,
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>

-- 
========================
Carl Gosselin CCIE Voice #15228
AltiZONE inc.
Mob: 514-458-9665
Blogs and organic groups at http://www.ccie.net
Received on Fri Feb 04 2011 - 22:20:48 ART

This archive was generated by hypermail 2.2.0 : Tue Mar 01 2011 - 07:01:49 ART