Re: RPC

From: Gaurav Thukral <pearlgaurav_at_gmail.com>
Date: Mon, 15 Nov 2010 12:11:24 +0530

Thanks a ton Andy.

Regards,
Gaurav

On Mon, Nov 15, 2010 at 12:06 PM, Andy Reid <ccie_at_reid.it> wrote:

> Hi Gaurav,
>
> I have my rack setup with 2 x APC 9212 masterswitches both equipped with
> APC 9606 Web/SNMP management card.
> With these I can independently manage the power to 16 devices remotely via
> SSH or HTTP.
> They only take 1RU and I purchased them from Ebay - they have been well
> worth the investment.
>
> regards Andy
>
>
> Jay McMickle wrote:
>
> I do, too. I have my 4 power outlets connected to a power strip.
>
> Outlet 1
> (backbone)
> 1x Frame-relay switch (3725)
>
> Outlet 2 (Routers)
> 6x 2811 routers
> Outlet 3 (Switches)
> 4x 3560 switches
>
> Outlet 4 (BB routers)
> 3x 2611 routers
> The Sentry Commander PT40 allows you to power all of the outlets up at once,
> but
> will release the power evenly outlet by outlet so that you don't trip
> your
> breaker. Very useful for me. I have 3 racks, each witih a PT-40 on it.
> One for INE workbooks (lab simulation workbooks)
> One for Global Knowleddge
> (lab simulation workbooks)
> One for IPExpert (technology based workbooks)
>
> I
> use all of my racks remotely while at work, as they are all at my house. I've
> been at this for 6 months and I haven't had any issues. The PT-40 also has an
> option for a modem so that you can dial into them, should your remote
> connectivity become unavailable.
>
> I hope this helps. Good luck to you on your
> studies and success.
>
> Regards,
> Jay McMickle- CCNP, CCSP, CCDP, MCSEhttp://mycciepursuit.wordpress.com/
>
>
>
>
>
> ________________________________
> From: Gaurav Thukral <pearlgaurav_at_gmail.com> <pearlgaurav_at_gmail.com>
> To: Jay McMickle<jay.mcmickle_at_yahoo.com> <jay.mcmickle_at_yahoo.com>
> Cc: Group study <ccielab_at_groupstudy.com> <ccielab_at_groupstudy.com>; Wayne
> Lawson <groupstudy_at_ipexpert.com> <groupstudy_at_ipexpert.com>; "groupstudy_at_cconlinelabs.com" <groupstudy_at_cconlinelabs.com><groupstudy_at_cconlinelabs.com> <groupstudy_at_cconlinelabs.com>
> Sent: Sun, November 14, 2010 7:29:54 AM
> Subject:
> Re: RPC
>
> But i have my 15 devices in my rack.
>
> Regards,
> Gaurav
>
> On Sun, Nov
> 14, 2010 at 6:03 PM, Jay McMickle <jay.mcmickle_at_yahoo.com> <jay.mcmickle_at_yahoo.com>wrote:
>
>
>
> I use a
>
>
> sentry commander PT40. It has 4 power outlets and 4 console
>
>
> connections that
>
>
> you can access via command line. Powering up/down my
>
>
> devices remotely for my
>
>
> rack saves me a ton of money on my electric bill so
>
>
> that they are only on
>
>
> when in use.
>
>
> Regards,
> Jay McMickle- CCNP,CCSP,CCDP
> Sent from my iPhonehttp://mycciepursuit.wordpress.com
>
>
> On Nov 13, 2010, at 6:16 PM, Gaurav
>
>
> Thukral <pearlgaurav_at_gmail.com> <pearlgaurav_at_gmail.com> wrote:
>
>
> Hi Guys,
>
> I have my own
>
>
> VOICE Rack. I wanna power cycle all the devices remotely
>
>
> what
>
>
> device i
>
>
> can use for that.
>
>
> Regards,
> Gaurav
>
>
> Blogs and organic
>
>
> groups at http://www.ccie.net
>
> _______________________________________________________________________
>
>
> Subscription information may be found at:
>
>
> http://www.groupstudy.com/list/CCIELab.html
>
>
> Blogs and organic groups athttp://www.ccie.net
> _______________________________________________________________________
> Subscription information may be found at:http://www.groupstudy.com/list/CCIELab.html
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at: http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net
Received on Mon Nov 15 2010 - 12:11:24 ART