Re: STP ROOT BRIDGE PROBLEM!!!!

From: Marko Milivojevic <markom_at_ipexpert.com>
Date: Fri, 18 Jun 2010 17:57:11 -0400

> Cat1-Cat2: Fa0/24
> Cat2-Cat3: Fa0/22
> Cat3-Cat4: Fa0/22
> Cat4-Cat1: Fa0/24

Small typo here. It should be:

Cat1-Cat2: Fa0/24
Cat2-Cat3: Fa0/22
Cat3-Cat4: Fa0/24
Cat4-Cat1: Fa0/22

--