Re: Inbound calls to the CME

From: Carlos G Mendioroz <tron_at_huapi.ba.ar>
Date: Sat, 12 Jun 2010 08:52:11 -0300

FXO supervision is a pain in the arm.

You may find
http://www.cisco.com/en/US/tech/tk652/tk653/technologies_tech_note09186a00800ae2d1.shtml
enlightening.

-Carlos

CCIE @ 12/06/2010 4:39 -0300 dixit:
> Hi experts,
>
>
>
>
>
> Once I get an outside call from my CME through the FXO interface even if the
> remote called disconnect my internal line keeps ringing??
>
> Any advice about that?
>
>
>
> Regards,
>
> Amin
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>

-- 
Carlos G Mendioroz  <tron_at_huapi.ba.ar>  LW7 EQI  Argentina
Blogs and organic groups at http://www.ccie.net
Received on Sat Jun 12 2010 - 08:52:11 ART