do they have another connection between them?
On Fri, Mar 12, 2010 at 10:55 PM, Nate Lee <natetlee_at_gmail.com> wrote:
> I have two switches who peer up using EIGRP then drop after a minute or so
> saying there is a K-value mismatch. I have verified both switches K values
> via show ip protocols and they are both set to defaults. Is there anything
> else that could give this error?
>
> Thanks,
>
> Nate
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>
-- Narbik Kocharians CCSI#30832, CCIE# 12410 (R&S, SP, Security) www.MicronicsTraining.com Sr. Technical Instructor YES! We take Cisco Learning Credits! Training And Remote Racks available Blogs and organic groups at http://www.ccie.netReceived on Fri Mar 12 2010 - 23:14:34 ART